Apex Pressure Limiting Valve 25mm 500kPa - LV25500
POA
Model: LV25500
Apex Pressure Limiting Valve 25mm 500kPa - LV25500
Use with EV25
Note: All limiting valves must be protected by a downstream expansion valve of the relative setting as prescribed above.
Application:
For extremely high flow, high demand mains pressure systems, eg. large homes, multi-storey apartments and commercial applications.
Standards:
- Complies with NZ Building Code G12 (2001)
- Manufactured to NZS 4608: 1992
- Cartridge Water marked AS1357.2 LICWMKA 02596
- Forged, high quality, corrosion resistant, DR brass body
- Extremely high flow rates - up to 250 litres a minute
- Pressure compensated to give constant outlet pressure regardless of inlet pressure
- Twin adjustable (200-600kPa), removable cartridges for easy servicing
- All valve seats are contained in cartridges - no need to remove valve body from system
- Can be installed in any orientation, for external application a cap is provided to protect cartridge
- No unions, no leaks
Flow Chart:
Installation:
- Refer to Specifcations Tab for installation guide.
- Do NOT install Limiting Valve in the ground.
- Do NOT apply heat near valve during installation.
- Install so that both hot and cold supplies are balanced.
- Can be installed in any orientation. For external application, cartridge must be at bottom.
- Must be installed with correct Expansion Valve fitted down stream of a limiting valve.
- To adjust outlet pressure use large Philips/Pozi screw driver, turn adjusting screw clockwise to increase (1 turn = 60 kPa [9psi])
Servcing:
- Filter must be cleaned regularly.
- Inlet: 25mm 1" BSP (male)
- Outlet: 25mm 1" BSP (male)
- DR forged body
- Length: 110mm
- Height: 190mm
- Maximum inlet pressure 2000kPa
- Maximum inlet tempreture 65°C
- Twin, integral 60 mesh (250 micron) strainers
Downloads | |
Apex Catalogue | |
pex Pressure Limiting Valve 25mm - LV25 |