Reliance Heatguard 20 (Blue) 20mm tempering valve - MIX 11125
Model: MIX 11125
Reliance Heatguard 20 (Blue) 20mm tempering valve - MIX 11125
The RMC HeatGuard tempering valves are suitable for domestic and commercial installation on water heater systems The HeatGuard is available in 15 mm and 20 mm nominal diameters with with male compression integral union fittings.
RMC's HeatGuard is a tempering valve that mixes hot water with cold water to deliver tempered water at a constant temperature throughout an entire house, building or system. HeatGuard is suitable for tempering the hot water supply to sanitary devices intended for personal hygiene purposes, where outlet temperature must not exceed a maximum of 50°C. HeatGuard is compatible with most storage water heaters. HeatGuard is available in 15 mm and 20 mm confi gurations.
-
Union connections
Valve easy to install and easy to remove for servicing of strainers -
Performance
More accurate control of outlet temperature – safer installations -
Strainers upstream of check valves
Protects valve and check valves from impurities in the water supply -
Tamper-proof adjustment
Special adjuster key eliminates chances of accidental adjustment -
Dezincification resistant
Meets Australian Standard for potable water supply -
Individually tested and calibrated
Every valve is tested to ensure higher quality and performance
Application:
RMC's HeatGuard is a tempering valve for use in hot water distribution systems. Fitting the valve at the hot water source ensures the delivery of constant temperature hot water throughout the system.
DO NOT USE on steam supplied systems.
Cold water supply temperature: | 5° C - 30° C |
Hot water supply temperature: | 60° C - 99° C |
Optimum outlet temperature range: | 40 C – 50° C |
Set temperature: |
Must be commissioned on site to achieve desired outlet
temperature
|
Accuracy of outlet temperature: | ±3° C - tested to AS4032.2 between 40° C and 50° C |
Minimum temperature differential:
(Between hot supply and outlet temperature)
|
15° C |
Supply pressure, static: | 1600 kPa maximum |
Supply pressure imbalance, dynamic:
(At time of commissioning)
|
2:1 maximum |
Maximum permitted pressure variation in either supply, in order to control outlet temperature to ±3° C:
(From supply pressure at commissioning)
|
±10% maximum |
Minimum fl ow rate: | 4 litres/min |
Fittings Supplied: | Male BSP Thread |
Downloads | |
HeatGuard Technical Specification Sheet |