Apex Pressure Reducing Valve (Feed Valve) 110 kPa - FV12.2
POA
Model: FV12.2
Apex Pressure Reducing Valve (Feed Valve) 110 kPa - FV12.2
Application:
Low and medium pressure hot water systems.
Standards:
- Complies with NZ Building Code G12 (2001)
- Complies with NZS 4608:1992
- Patent No. 504476
- Pressure compensated to give constant outlet pressure regardless of inlet pressure.
- Silicon rubber diaphragm and washer - no heat loop required.
- N.Z. forged, high quality, corrosion resistant DR brass body
- Machined, assembled and 100% tested in N.Z.
- One-piece forged brass fork with no water paths - no leaks!
Flow Chart:
Installation:
- Refer to Specifcations Tab for installtion guide
- Can be installed in any orientation.
- Do NOT install in the ground.
- Do NOT apply heat near valve during installation.
- Valve may require adjustment on site. To increase pressure turn adjusting screw clockwise (1 ½ turns = 1 metre head).
- Valve must be either valve vented or open vented.
- For increased flow rates or inlet pressure below 200 kPa [29psi], two valves in parallel may be required.
- Where two valves are in parallel, each must have isolating valves on inlet.
Inlet: 15mm, 1/2" BSP (male)
Outlet: 20mm 3/4" BSP (male)
Length: 138mm
-
Set Pressures:
- FV3.7 - 35 kPa [5psi]
- FV7.6 - 65 kPa [9psi]
- FV12.2 - 110 kPa [16psi]
-
Adjustable pressure range:
- FV3.7 & FV7.6 - 15 to 100 kPa [2 to 14psi]
- FV12.2 - 50 to 150 kPa [7 to 22psi]
-
Maximum Inlet Pressure and Temperature:
- Maximum inlet pressure: 2000 kPa [290psi].
- Plastic Cap: 40˚C
- Brass Cap: 80˚C - hot water valve
- Minimum temperature: 1˚C