Reliance HeatGuard Ultra (Orange) 20mm Tempering Valve - MIX 11130
Model: MIX 11130
Reliance HeatGuard Ultra (Orange) 20mm Tempering Valve - MIX 11130
RMC's HeatGuard Ultra is a High Performance and High Temperature tempering valve that mixes hot water with cold water to deliver tempered water at a constant temperature throughout an entire house, building or system. The HeatGuard Ultra is suitable for most domestic applications and for sanitary devices intended for personal hygiene purposes, where outlet temperature must not exceed a maximum of 50°C . HeatGuard Ultra is ideal for use in installations where there are fl uctuations in supply conditions and in solar hot water installations where a booster pump is used. HeatGuard Ultra is available in 15 mm and 20 mm confi gurations.
-
High thermal endurance
Will endure the extreme temperatures present in solar installations -
High Performance specifications
Designed especially for situations requiring high valve specifi cation such as fl uctuating supply pressures -
Union Connections
Valve easy to install and easy to remove for servicing of strainers -
Performance
More accurate control of outlet temperature – safer installations -
Strainers upstream of checks
Protects valve and check valves from impurities in the water supply -
Tamper-proof adjustment
Special adjuster key eliminates chances of accidental adjustment -
Dezincification resistant
Meets Australian Standard for potable water supply -
Individually tested and calibrated
Every valve is tested to ensure higher quality and performance
RMC's HeatGuard Ultra is a High Performance and High Temperature Tempering Valve suited for use with solar, instantaneous and heat exchange (continuous fl ow), and pumped ring main hot water distribution systems. HeatGuard Ultra is suitable for use as a point of use tempering device.
DO NOT USE on steam supplied systems.
Cold water supply temperature: | 5° C - 30° C |
Hot water supply temperature: | 60° C - 99° C 1 |
Optimum outlet temperature range: | 40 C – 50° C 2 |
Set temperature: |
Must be commissioned on site to achieve desired outlet
temperature
|
Accuracy of outlet temperature: | ±3° C - tested to AS4032.2 between 40° C and 50° C |
Minimum temperature differential:
(Between hot supply and outlet temperature)
|
10° C |
Supply pressure, static: | 1600 kPa maximum |
Supply pressure imbalance, dynamic:
(At time of commissioning)
|
2:1 maximum |
Maximum permitted pressure variation in either supply, in order to control outlet temperature to ±3° C:
(From supply pressure at commissioning)
|
±15% maximum |
Minimum fl ow rate: | 4 litres/min |
Fittings Supplied: | Male BSP Thread |
Downloads | |
HeatGuard Ultra Technical Specification Sheet |